Imagine going a day or two days or a week without water.
Tracer wire for water line.
If you are planning on burying the wire 12 gauge insulated copper wire open to the ground at the far end is a great choice.
The red wire is for electric.
Taping the wire to the pipe helps prevent damage to the wire during back filling or when digging around the pipe in the future.
Installation of color coded warning tape one foot above the pipe will enhance utility id during excavation.
The coating is normally polyethylene the same.
Yellow is for gas orange is for communication blue tracer wire is for potable water and green is for sewer.
Tracer wire should not be wrapped around pipe or connectors except at the riser.
Water pipe tracer wire.
Tracer wire shall not be wrapped around the pipe.
That s why tracer wire is laid underground with sewer lines.
They supply high quality wire that will help you complete your projects.
Exposed ends such as at meter risers are not allowed and shall be protected from exposure.
Step 3 ground.
New tracer wire designed specifically for underground use is no longer solid copper but copper clad steel for better strength to prevent breakage.
Luckily tracer wire is used for this application as well.
Once a pipe is laid down tracer wire is placed along it s length and buried next to the pipe.
Lay mainline trace wire continuously by passing around the outside of valves and fittings on the north or east side.
No bare tracer wire shall be exposed either below or above ground.
Tracer wire shall not be connected to existing foreign conductive utilities.
Plumbersstock we carry tracer wire from a top manufacturer regency wire.
When other alternatives are used like electrical tape corrosion will result causing your locate signal to stop at the connection point.
The tracer wire should be placed in the same orientation to all installed pipe.
Since water pipes are found both underground and within buildings and homes tracer wire must be.
The tracer wire shall be laid within 6 inches of the plastic pipe where practical and directly above if possible.
Water system a mainline trace wire must be installed with all service lateral trace wires properly connected to the mainline trace wire to ensure full tracing locating capabilities from a single connection point.
They have been industry leaders since 1985.
This wire is what s actually searched for if the pipe itself needs to be located hence the name.
Main line splice to service line connection shall be specifically manufactured for use in underground trace wire installation shall be dielectric silicon filled to seal out moisture and corrosion and shall be installed in a manner so as to prevent any uninsulated wire exposure.
Tracer wire which is also called locating wire or locator wire is used to assist in locating pipes and other lines after they ve been buried in the ground.
A tracer wire system is only as good as its weakest connection.
A coated copper clad steel tracer wire of 12 gauge or larger kub item 300362 shall be installed with all buried plastic mains and services.
Waterproof corrosion proof connectors protect vulnerable wire splices and keep the locate signal flowing across connections.